AdcExample.vi demonstrates how to set and get properties values of ADC port and its channels.
Application Block Diagram is shown below.
All components are connected sequentially and all error inputs and outputs should be connected. First, we call DlnConnect.vi component and connect to proper inputs port
and host
values. Then we call DlnOpenDevice.vi component, which opens any connected DLN-series device. DlnAdcPort.vi gets Dln.Device
reference and port
number as inputs and we get Dln.Adc.Port
and Dln.Adc.Channel
references as outputs. Connect Dln.Adc.Port
and Dln.Adc.Channel
references outputs to Property Nodes
. To add Port or Channel properties right-click on Port Property Node choose Add Element, then right click again on the new element and choose "Select Property" list. After property is added you can change property to read or write also by right-clicking on property element.
After all operations with ADC module are done, close Dln.Device
reference and finally call DlnDisconnect.vi to close connection with Dln Server and Dln.Library
reference.